(PDF) Deepwater Horizon Blowoout Preventer Failure

FTA Leg -3 AnalysisWe called the third leg of our tree as a common cause failure which comprised of Human error, Hydraulic failure, mechanical failure MUX cable failure, Press button control Failure.Hydraulic failure:-BOP as a whole is a hydraulic system which had 7 mechanisms which used hydraulic energy for functioning. (PDF) How to analyze gear failures - ResearchGateDec 08, 2020 · The failure investigation of a gear should be planned carefully to preserve evidence. Ideally, the analyst should visit the site and inspect failed components as soon after failure as possible.

CALIFORNIA PUBLIC UTILITIES COMMISSION Safety and

Nov 27, 2017 · disconnected. The expander plug contained gas from 2003 to 2013 while the main functioned as a low-pressure distribution main. In 2013 the main was uprated to high-pressure distribution and the plug did not dislodge until 2017. After the failure of the expander plug, gas was able to migrate from the abandoned service tee into the Failure Investigation Report Pig Trap Gas Release Failure Investigation Report Pig Trap Gas Release Activity ID 127555 The operator determined during the post-incident investigation that the ¾ ball valves and the safety interlock on Safety plug to be opened from side as per current procedure. A 2 ball valve was GoogleSearch the world's information, including webpages, images, videos and more. Google has many special features to help you find exactly what you're looking for.

How to Avoid PRV Performance Problems - Valve Magazine

Relief valve #2 had a set pressure of 305 psig. After media flowed through the economizer, the system pressure dropped from 483 psig to 445 psig. Therefore, relief valve #2 was set below the normal operating pressure and would be open at all times. Further investigation revealed that relief valve #2 had an isolating valve installed on its inlet Plug the Holes in the Swiss Cheese Model - EmersonInvestigations have revealed that most industrial incidents include multiple independent failures. Imagine each layer of protection as a slice of Swiss cheese (3), with the holes representing vulnerabilities to failure (Figure 2). For an incident to occur, the holes in the slices of Read the U.S. Chemical Safety Board investigation report Failure to wait xxxxxx xxxxxx xxxxxx technician xxxxxx assistance made xxxxxx Junior service technician xxxxxx a mistake xxxxxx removing xxxxxx plug xxxxxx xxxxxx propane tank valve:Printed guidelines on xxxxxx to safely remove xxxxxx plug xxxxxx xxxxxx valves did not exist

Technical Bulletin / Safety Alert - VLI

DES2009-TBSA-02 Page 1 of 12 Technical Bulletin / Safety Alert Unique ID No:DES2009-TBSA-02 Rev:0 (This document supersedes SMV TBSA0809-02) Subject:Machine failed to shutdown on Stop/Run Valve & Emergency Shutdown Valve (Strangler). Date:14/8/09 Applicable to:All JUG-A-0 UL/UV V2 & V3 Machines Note:Minimum PPE required to carry out any inspections contained in this TBSA Three Hispanic Acetylene Manufacturing Plant Workers the automatic water valve to open. The only device to prevent acetylene gas from traveling back through the water line was a gumdrop check valve. This valve contained a rubber-coated plug which closed off when gravity or a back flow of gas causes the plug to fall into the seat at the bottom of the valve, sealing the pipe off. (See Graphic 2). Troubleshooting - Rob RobinetteThe Amp is Completely Dead If the amp is completely silent (no speaker hum or hiss at all) then the problem can be just about anywhere in the amp but you should suspect a bad tube, blown fuse or the power supply in that order.. Try a new rectifier tube. Try plugging in a guitar cable, turn up all the amp's volume, gain and master volume controls up a little and touch the tip of the guitar

U.S. CHEMICAL SAFETY AND HAZARD INVESTIGATION

complete flow blockage, which occurred due to the sudden failure of a control valve. 4. The control valve failed when an internal plug unthreaded from the valve stem, closing the valve. The only existing bypass valve was manually operated and became inaccessible following the hydrocarbon release. 5.